How an alarm system works

All alarm systems have three basic parts:
1) Control equipment, the "brains" of the system which contains the microprocessor,
        the programming, power supply, and the means to arm/disarm the system
2) Detectors, the "senses" which see, hear, smell, or feel changes electronically
        and are connected to the control equipment.
3) Signaling, the "mouth" which provides notification of a problem.  

CONTROL EQUIPMENT

General Description
   
The control panel contains the computer which determines the capabilities of the system, and the system backup battery. All components of the alarm system are connected to the control panel either by wires or wireless devices. The control panel is usually a locked metal box installed near electrical and telephone sources. The newest generation of control panels permit remote programming of the system. Control equipment which is listed with Underwriter's Laboratory (U.L.) meets the highest standards.
Alarm Microprocessor
   
Also called the computer or "brain" usually determines these characteristics:
            Type/model of keypad                             History buffer
            Number of zones                                    Automatic arming
            Number of user codes                             Remote programmability
            Number of partitions                               Battery test
            Detector tests                                        Customized arming/disarming
Power supply: primary/standby

Alarms have two sources of power: a primary source which is a plug-in 110 volt transformer and a standby battery. The battery provides a regulated 12 volt power supply so that the microprocessor and detectors operate properly and it also serves as a standby power source. Much like a car battery, the alarm battery is rechargeable, but does have a limited life span of about 3-5 years. The alarm microprocessor runs a battery check every 24 hours. When the battery needs to be replaced, a low battery condition is indicated on the keypad and a signal is transmitted to the monitoring facility for those customers with monitored systems.
Keypads
Pushbutton keypads with programmable passcodes are now universally used to arm/disarm alarm systems. Keypads are normally located at the main entry/exit points and master bedroom. Indicator lights or word display show the status of the system, problems, and open zones. Customized arming permits activation of selected zones or areas, e.g. arming doors/windows while excluding the motion detector. A special "bypass" permits arming the system with malfunctioning or non-operational detectors.
Commercial users usually give different codes to various employees. These systems record who arms/disarms the system, the time of the event, automatically arm themselves, and may limit access to certain employees.

DETECTORS

General Description

The choice of detectors determines what conditions activate the alarm system. Detectors are categorized by Intrusion (Perimeter/Interior), Fire, Gas, and Environmental. Detector selection needs to balance risks, system stability, and budget.


Intrusion Detectors: Perimeter
recessed contact.gif (12186 bytes)

Doors and windows are protected using magnetic switches/contacts to sense their opening. Breaking glass is now detected by sensors placed in a room rather than on the glass itself.

Intrusion Detectors: Interior
ds940.gif (21392 bytes)


Motion detectors are used to detect movement in high traffic and high risk areas. They use various methods of detecting movement. The most common motion detector is the Passive Infra-Red (PIR) which senses body heat. New PIRs are able to operate even with pets. Other motion detectors utilize micro-wave or ultra-sonic to detect movement. Photo-beams are used in large commercial applications. Floor mats are now obsolete.

Fire

dxs72 smoke.jpg (4008 bytes)


Fire detectors sense smoke and/or heat. Smoke detectors use two different sensing methods: photo-electric and ionization. Photo-electric smoke detectors are preferred by most Fire Marshals and are the type normally installed by alarm companies. Ionization smoke detectors are what is normally installed by electricians in a home. Heat detectors are activated when the room temperature reaches a set temperature, usually 135 degrees, or when there is a rapid increase in room temperature. Heat detectors are usually placed in garages or other areas where life safety is not the primary risk. Many models of photo-electric smoke detectors also have a built-in heat detector. Many cities now require a smoke detector in every bedroom, as well as, common hallways.

Gas Detectors

The two main types of gas detectors are: natural gas and carbon monoxide. Gas detectors sense one or the other not both types of gas. Carbon monoxide detectors are most common, since this deadly gas is tasteless and odorless.

Environmental Detectors

Low temperature, water, sump pump and furnace failure are only some of the environmental detectors available. Some appliances have built-in sensors which can be connected to an alarm system. 

SIGNALING

General Description
   
Sirens sounding, lights flashing, the police/fire department being notified are what most people associate with an alarm system. Annunciation of an alarm usually occurs locally and/or remotely.
Local Annunciation

MPI35siren.gif (11009 bytes)
    Local annunciation devices, sirens, bells, and flashing lights, alert individuals at the premise that the alarm has been activated. To comply with noise ordinances, most alarm systems have an automatic time out, and only use interior sounding devices.

Remote Notification

The assurance that professional help is rapidly summoned to an alarm situation is the purpose of remote notification.
    One-way alarm notification is usually done when the alarm system sends an electronic signal over the telephone lines to a manned facility. Cellular telephone and radio transmitters are also used to send alarm signals. A monitoring facility/central station is used by most alarm companies to provide this service and ones listed by U.L. (Underwriters Laboratory) must meet special insurance industry standards. Most alarm systems today are monitored at  facilities which are hundreds of miles away, some of which provide specialized services.
    Two-way voice alarm notification permits the alarm company to "listen-in" and "speak" over the alarm system. This is done microphone/speakers and especially trained operators. Two-way voice is an important advancement where personal safety and alarm verification are a concern.
    Cellular backup is used to insure that the alarm transmission is received by the alarm company even if the telephone line is cut or out of service. 